Chapter 7 Parameters
ASDA-B2
7-94
Revision May, 2018
P4-20
DOF1
Offset Adjustment of Analog Monitor
Output (MON1)
Address: 0428H
0429H
Operation
Interface:
Panel / Software
Communication
Related Section:
6.4.4
Default:
Factory setting
Control
Mode:
ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Format: Decimal
Settings: Offset adjustment value (cannot reset)
P4-21
DOF2
Offset Adjustment of Analog Monitor
Output (MON2)
Address: 042AH
042BH
Operation
Interface:
Panel / Software
Communication
Related Section:
6.4.4
Default:
0
Control
Mode:
ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Format: Decimal
Settings: Offset adjustment value (cannot reset)
P4-22
SAO Analog Speed Input Offset
Address: 042CH
042DH
Operation
Interface:
Panel / Software
Communication
Related Section: N/A
Default:
0
Control
Mode:
S
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Format: Decimal
Settings: Users manually adjust the offset