ASDA-B2
Chapter 6 Control Modes of Operation
Revision May, 2018
6-45
NOTE
Please refer to parameter P1-04, P1-05 for proportional setting of
analog output voltage.
For example: P0-03 = 01 (MON1 is the analog output of motor
speed; MON2 is the analog output of motor torque (force))
MON1 output voltage
8
.
(unit
:
Volts)
MON2 output voltage
8
.
(unit: Volts)
P1-03
AOUT Polarity Setting of Encoder Pulse Output
Address: 0106H
0107H
Operation
Interface:
Panel/Software
Communication
Related Section:
Section 3.3.3
Default:
0
Control
Mode:
ALL
Unit: -
Range: 0 ~ 13
Data Size: 16-bit
Display
Format:
Hexadecimal
Settings
:
Polarity of monitor analog output
0: MON1 (+), MON2 (+)
1: MON1 (+), MON2 (-)
2: MON1 (-), MON2 (+)
3: MON1 (-), MON2 (-)
Polarity of encoder pulse output
0: Forward output
1: Reverse output
Polarity of monitor analog output
Polarity of encoder pulse output
Not in use