WARNING!
Bending up of the socket sleeve!
If the socket sleeve is placed incorrectly on the collector brush, the socket sleeve bends up,
the socket sleeve is damaged and the contact with the brush is minimized.
→
Ensure the socket is correctly positioned to prevent the socket sleeve from bending up!
CAUTION!
Contact problems or increased heating!
→
Clean the sliding contacts before commissioning and remove soiling, oxidation, pitting cor-
rosion and other impurities by means of a brass brush or abrasive paper (320 grit).
DANGER!
Risk of damage when cleaning the conductor rail!
When cleaning, only loose or lightly adhering dust or foreign substances may be removed.
→
Do not use contact spray
(formation of silicon carbide/abrasive and/or damage of plastic
parts).
→
Only use abrasives or brushes as tools for removing heavy build-ups at minor burns under
supervision.
→
Persistent use with removal of the lubricant layer or running surface damages the rail (see
also WV0800-0001 and WV0800-0004)
Typical installation errors that have a negative effect on the running behavior of the current collectors:
Conductor rails are not correctly engaged in the hanger clamp.
Rail bends are tapered due to progressive bending.
Switches and lifters are incorrectly set (end positions, dimensional tolerances) or yielding.
Incorrect current collector connecting cable.
Current collector connecting cable not used as (not free of directional and tensile forces).
Installation positions are not within specification; permissible tolerances are exceeded in bends and curves.
Rail joints and transfers have not been deburred.
Use the QR code (“click” or “scan”), to watch our animation
Mounting EMS Current Collector onto Towing Plate.