Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 64 of 128
6.3.3.5.1
Determine the number of expansion modules
The number and position of the expansion modules depends on the system layout, the operating temperature range and existing
building expansion joints or customer-specific support profiles.
Procedure:
1.
Determine the required expansion modules at building expansion joints and support profile expansions.
2.
Determine the required expansion modules for straight support profile areas from 8 m.
NOTE!
When planning, consider all temperature fluctuations within the entire life cycle of a system!
A hall with a temperature fluctuation of 30 K is assumed for the facility system in Fig. 69. The corresponding values can be taken
from Table 2 and Table 3:
No expansion unit
required
Interme-
diate
length
“a”
Freely expanding
end
Example:
Possible total length with “n” expansion units and
2 freely expanding ends
1
2
3
4
5
∆ t
10 K
≤ 8 m
121 m
100 m
321 m 442 m
563 m
684 m
805 m
20 K
≤ 8 m
60 m
100 m
260 m 320 m
380 m
440 m
500 m
30 K
≤ 8 m
40 m
100 m
240 m 280 m
320 m
360 m
400 m
40 K
≤ 8 m
30 m
100 m
230 m 260 m
290 m
320 m
350 m
50 K
≤ 8 m
24 m
100 m
224 m 248 m
273 m
297 m
321 m
Table 2: For 1x20 mm expansion unit with complete utilization of the expansion gap
No expansion unit
required
Intermedi-
ate length
“a”
Freely expanding
end
Example:
Possible total length with “n” expansion units and
2 freely expanding ends
1
2
3
4
5
∆ t
10 K
≤ 8 m
60 m
100 m
260 m
320 m
380 m
440 m
500 m
20 K
≤ 8 m
30 m
100 m
230 m
260 m
290 m
320 m
350 m
30 K
≤ 8 m
20 m
100 m
220 m
240 m
260 m
280 m
300 m
40 K
≤ 8 m
15 m
100 m
215 m
230 m
245 m
260 m
275 m
50 K
≤ 8 m
12 m
100 m
212 m
224 m
236 m
248 m
261 m
Table 3: For 1x20 mm expansion unit when using the setting aid