Interval
Servicing task
To be per-
formed by
Check the sliding contact insulation for cracks and abrasion.
→
replace the current collector if the sliding contact insulation is damaged or cracked.
Check the insulation for wear, soiling and burn marks.
→
If necessary, clean insulation profile or repair the site of damage.
Ensure that there are no constrictions inside the individual poles of the insulation
profile (dust or adhering dirt).
→
Clean the insulation profile with a vacuum cleaner or brush or replace.
Ensure that the insulation is not affected by foreign bodies (shavings, fluids, con-
tamination, etc.; risk of short circuit).
→
Clean or replace components, if it is not possible to fully restore the insulating prop-
erties.
Functional test
:
→
Check for the presence of springs.
→
Check the correct installation position of the current collector (see Section 6.3.4).
→
Change the fastening position in the event of deviation.
The required contact force is ensured by the correct fastening position of the cur-
rent collector.
However, if measurement of the contact force is required, the following steps must
be taken:
→
Attach a suitable spring balance to the current collector arm as close as possible to
the middle joint of the two current collector heads. Pull the current collector head
vertically away from the conductor bar using the spring balance.
→
Reading the measured value: Check the value measured by the spring balance
when the sliding contact lifts off the sliding surface! The contact force must be 9 ±
0.5 N.
Check the freedom of movement of each individual current collector arm.
→
If necessary, clean or replace entire current collector.
Check the vertical and lateral tolerance of the current collectors relative to the con-
ductor rail.
→
If necessary, correct the mounting position.
Ensure that the connecting cable is not twisted at the current collector head
and that the cable loop is not exerting directional forces on the current col-
lector head. This must apply in every position of the current collector arm.
→
If necessary, clean insulation profile or repair defect.