![Conductix-Wampfler SingleFlexLine Program 0815 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/conductix-wampfler/singleflexline-program-0815/singleflexline-program-0815_operating-instructions-manual_2651969015.webp)
Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 15 of 128
2.8.3
Danger due to dust and vapors
WARNING!
Danger of sensitization, irritation of the mucous membranes and respiratory
diseases due to dust and vapors!
Abrasions from the sliding contact carbon brushes collect in the conductor rails
and the guideway. This dust is very fine and is a health hazard. Frequent han-
dling can result in sensitization. Persons who frequently spend longer periods in a
heavily used system without protective equipment must reckon with the following
consequences
:
Irritations of the mucous membranes
Respiratory diseases
Cancer
These consequences must also be expected if accumulations of dust are handled
without proper care (e.g., removal of dust using compressed air).
→
In workplaces with long-term exposure and heavily trafficked facilities, take ef-
fective measures to protect employees from the dust.
→
During all work on the conductor rail system in which collected dust can be
stirred up, wear personal protective equipment. In particular, wear personal pro-
tective equipment when cleaning the system.
Protective eyewear
Protective dust mask Class FFP3 (observe local regulations)
Protective gloves
Disposable coveralls
→
Before starting work, clean the conductor rail in accordance with regulations.
There are special instructions for this task; see Section 9.
→
Protect the surroundings during cleaning works, for instance by covering or re-
moving warehouse goods and blocking access to those areas in which dust
could fall down on persons.
→
Do not blow out dust with compressed air
; vacuum it up instead. The vac-
uum cleaner must be equipped with a Class H fine filter.
→
Do not eat, drink or smoke during work!
DANGER!
Poisonous vapors/gases in case of fire!
The standard insulation materials contain PVC. Poisonous vapors/gases (HCL) can be pro-
duced during fires.
→
The building must be evacuated immediately.
→
Notify the fire department.