Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 94 of 128
WARNING!
Risk of wear and damage!
The distance from the securing base surface of the current collector to the running surface of the con-
ductor rail is an important functional dimension. This dimension changes in curves if the current col-
lector is not installed directly under the wheel contact point of the EMS hanger. If the distance from
the wheel contact point is too great, the permissible tolerances may be exceeded in tighter curves.
Result: Damage, high wear
→
Compliance with the installation tolerances must therefore be checked in the tightest curved section!
Fig. 130: Protect unoccupied current collector connecting cable with the protective cap provided (08150A / B…; 08150x…)
NOTE!
The protective cap is supplied pre-installed on the current collector. A replacement protective
cap can be ordered as a packing unit with Order No.: 08-A025-0080!
Install all current collector cables with high flexibility and without tensile or directional forces!
Fig. 131: Comparison of the correct and incorrect position of the socket sleeve