![Conductix-Wampfler SingleFlexLine Program 0815 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/conductix-wampfler/singleflexline-program-0815/singleflexline-program-0815_operating-instructions-manual_2651969060.webp)
Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 60 of 128
→
Slide the last conductor rail bend with the connector into the rail opening of the first conductor rail bend (see Fig. 66).
Fig. 66: Connect the last connection point
→
Slide the connector cap over the connection point from behind and mount it in the insulating profile (see Fig. 62 - Fig. 64).
→
Mount the first conductor rail bend and the last conductor rail bend in the hanger clamp.
→
Connect or mount all other poles in the same way.
Use the QR code (“click” or “scan”), to watch our animation
Mounting Plug-in Connector in Closed Slip Ring Applications.
1.
2.