Re-mount the conductor rail with the installed air gap insulation section in the hanger clamp. The distance from the rear edge of
the end cap to the hanger clamp is 30 mm (see Fig. 104). Ensure that the air gap insulation section is in contact with the support
structure and not with a recess (see Fig. 106 and Fig. 105).
Fig. 104: Distance from the rear end cap edge to the hanger clamp
Fig. 105: Air gap insulation section is in contact with the support struc-
ture
Fig. 106: Air gap insulation section is in contact with a recess
Use the QR code (“click” or “scan”) to see our animation
Mounting Air Gap Insulation
Section.
30 mm