After mounting the connector cap, check the connection for solidity by gently pulling.
If the conductor rails can be pulled apart, the connector clamp is most likely incorrectly mounted (see
Fig. 49).
→
Attach the connector cap centrally from behind and clip it into the insulating profile.
→
Engage the conductor rails in the hanger clamps (see Fig. 52).
Fig. 52: Support profile with a conductor rail installed
CAUTION!
Conductor rails can become deformed when bent!
→
Check conductor rail bends for the correct profile since conductor rails can deform when bent in
the area of the insulation.
→
Push a current collector through the conductor rail by hand. The current collector must slide
through the conductor rail bend without jamming.
→
For a PE
plus
rail, use a PE
plus
current collector with a broader brush
→
If the connector cap cannot rest on the guideway profile, hanger clamps must be placed at maximum distances of 200 mm on
both sides of the connector position (see Fig. 53).