3.2.1
Lengths
Max. length of the installed conductor rail
Any, depending on the line feed design
Conductor bars
Max. 4000 mm (standard), 6000 mm and short lengths on request
Min. permissible conductor bar length
300 mm
Supplementary length per connection point
10 mm
3.2.2
Installation orientation
WARNING!
Danger due to increased wear or damage!
→
Install the current collector with its central axis exactly on the central axis of the conductor rail.
→
The mean distance between the outrigger axis and the contact surface must be precisely complied
with.
WARNING!
Loss of contact or increased heating!
Risk of injury due to loss of contact or increased heating if the current collector is operated outside the
permissible installation position.
3.2.3
Tolerances
The conductor rail must be installed within the following tolerances. Conductix-Wampfler does not accept any responsibility for the
conductor rail's correct functioning if these tolerances are not observed. In such a case, Conductix-Wampfler does not accept any
liability for problems that arise if the conductor rail system is not functioning correctly.
Conductor rails
X: ±3 mm; Y: ±1 mm (see Fig. 1)
Current collector*
X: ±10 mm; Y: ±10 mm (X: ± 15 mm, Y: ± 15 mm)
Force with which the current collector contacts the rail
Approx. 9 N
*depending on the current collector type
Fig. 1: Conductor bar 0815 coordinate system
Y
X
Z
Y
X
Z