Fig. 11: End cap with line feed
Fig. 12: End cap without line feed/crimping cable lug
End caps/end cap units/line feed
These are used as insulating termination of rails and as
guides for the sliding contact at a transfer. At a transfer, the
current collector is guided from one rail section to the follow-
ing section. The end cap unit consists of several end caps
and a mounting plate or a mounting bar for multi-pole ar-
rangements.
End caps and connectors are available as passive compo-
nents and as line feeds. These components are similar to
the passive components but have the option of connecting
an electrical supply cable. The clamping unit for line feed
modules differs from the passive components.
1 = End cap
2 = Clamping unit with crimping cable lug and connecting
cable
3 = Crimping cable lug for connecting cable
4 = Clamping unit without crimping cable lug and connecting
cable
The connection is made through crimping cable lugs for a
1.5 mm
2
–6 mm
2
conductor cross-section. For phases, dou-
ble insulated connecting cables must be provided for volt-
ages > 48 V.
Fig. 13: Expansion module with 16 mm expansion gap
Expansion module/Expansion unit
The expansion module/expansion unit is used to compen-
sate for the thermal expansion of the installation struc-
ture/EMS rail and conductor rail.
Building expansion points must be taken into account in the
installation of the conductor rail system.
Observe Section 6.3.3.5 for the mounting.