Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 113 of 128
The following table covers the most usual test steps. You can find details for cleaning and maintenance in WV0800-0001 and
WV0800-0002. The cleaning distance is individual and depends on the degree of contamination and the intensity of the use of the
system. Do not remove the patina under any circumstances! You can find details on the use of copper rails in WV0800-0004.
Interval
Servicing task
To be per-
formed by
Daily
Visual inspection
Is there heavy soiling or objects in the conductor rail?
Operators
4 weeks after
commission-
ing/500 km
Thereafter
:
Quarterly/semian-
nually
Visual inspection
:
Check whether the contact areas of the sliding contacts are worn.
→
If the wear limit “a” (ratio between insulation and sliding contacts) has been reached
or exceeded, replace the current collector
Fig. 132: Sliding contact wear limit
2
The wear limit of PE equals 2 mm to ensure the PE func-
tion, particularly with PE
plus
.
1
The tolerance varies according to the current collector type (see Section 6.3.4).
Pos. Name
1
Contact surface of
the conductor rail
2
Middle joint
3
Spring
Wear Limit “a” Type of Current Collector
1 mm
Phase
2 mm
PE
2
Current Collector
Type
Distance
Axis
Tolerance
081506…
081507…
65 mm
X
±10 mm
Y
±10 mm
081508…
081509…
80 mm
X
±10 mm
Y
±10 mm
08150A…
08150B…
92 mm
X
±15 mm
Y
±15 mm
Technician
For other current collec-
tors see Section 6.3.4