Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 120 of 128
Fault
Cause
Corrective measures
cable, replace if necessary. Check
the installation position at various
points in the system.
Collision with system components
Check the system's layout, fasten
the affected components in such a
way that they cannot be collided
with, replace damaged compo-
nents.
Abrasive dust has collected at one of the more frequently
used transfer points (where the direction of travel is re-
versed).
Adjust the consumer's movement
profile. Move over the end position
to push the collected abrasive dust
out of the conductor bar. Clean the
conductor bar.
Insulating profile is not en-
gaged in the hanger clamp.
Conductor rail has not been properly mounted.
Clip in the insulation profile, check
components, replace if necessary
Use of damaged components.
Replace damaged components.