Mount or connect the further conductor rail bends in the same way in the customer's support structure (substructure)
NOTE!
The conductor rail must not be bent further when the connector is mounted!
→
Before the last conductor rail bend is mounted in the hanger clamp, slide the connector into the end of the last conductor rail
bend up to the stopper (see Fig. 60).
→
Mount the last conductor rail bend (Pos. 7) in the hanger clamp (B) up to, but in, the last hanger clamp (A) in order for the last
connection point to be flexible. This means that the end of the first conductor rail bend (Pos. 6) and the end of the last conductor
rail bend (Pos. 7) are not yet mounted in the hanger clamp (A) and are now hanging across from each other (see Fig. 65).
The smaller the radius of the conductor rail bend, the greater the risk that the bend will be bent further
or deformed when it is connected. It may therefore be necessary to not mount the conductor rail bend in
more than one hanger clamp.
Fig. 65: Mount the last conductor rail bend