Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 67 of 128
No.
Route
Route characteristics
Number of
expansion
modules
Note
[3]
- Short segment
- Length: < 8 m
-
[4]
- Straight segment with a
building expansion point
< 40 mm
2
When determining the num-
ber of expansion modules, it
must be taken into account
that the expansion gap of the
expansion module includes
the building expansion point
and the thermal expansion
of the conductor rail, e.g., the
expansion gap of the expan-
sion module is always larger
than the building expansion
point.
In this case, it is sometimes
necessary to omit the fixed
points between two expan-
sion modules.