![Conductix-Wampfler SingleFlexLine Program 0815 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/conductix-wampfler/singleflexline-program-0815/singleflexline-program-0815_operating-instructions-manual_2651969037.webp)
Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 37 of 128
NOTE!
A clearance to the side of the conductor rail of at least 4 mm from metal components
must be maintained (see Fig. 20) to prevent mechanical collisions and guarantee suffi-
cient electrical insulation distances!
Fig. 20: Side clearance of at least 4 mm
6.2
Provide additional protection against accidental contact at the conductor rail end
An end cap is attached to the conductor rail end as protection against contact. In the case of double current collectors, a sliding
contact that is
under voltage
can protrude from the end cap at the end of the conductor rail during operation. Touching this sliding
contact may cause injury due to an electrical shock as well as by falling or being thrown across the room. The system operator must
ensure that the current collector does not protrude or must ensure that the danger area is inaccessible (e.g., by providing protection
against contact).
CAUTION!
Take constructional protective measures!
→
Use control technology to ensure that the current collector never travels beyond the end of the
conductor rail.
→
Also fit a contact guard that will safely cover the sliding contacts if they leave the conductor rail!
CAUTION!
Alert personnel to the hazard!
→
Attach a sign stating “Risk of Death due to Electrical Shock” with the relevant hazard symbol in all
areas with components under voltage.