![Amsco Century Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/amsco/century/century_operators-manual_2936190082.webp)
8-10
129373-496
Operating Instructions
Programming Cycle Values
•
Pressing
UNDER TEMP
advances display to screen #35. Enter under
temperature value using the numeric keypad. Temperature appears on
display as it is being entered.
If an under temperature alarm occurs, cycle operation will hold until the
sterilize temperature recovers. Once minimum temperature is reached,
sterilize phase may be programmed to either restart or resume at the time
when the alarm is cleared. Current programmed setting is shown in the
display screen, as indicated below.
35
CHANGE VALUES - UNDER TEMP
RETURN
1
2
3
4
5
6
7
8
9
←
←
←
←
←
0
→
→
→
→
→
STERILIZE
TIME RESUME
SET UNDER TEMP
1.0 C
The sterilize temp.
minus the under
temp. is the minimum sterilize
temp.
before an under temp.
alarm occurs.
If the alarm clears,
the sterilize time
will RESTART.
Pressing STERILIZE TIME RESUME will program control to resume the
sterilize phase time once the alarm clears.
•
Pressing
OVER TEMP
advances display to screen #36. Enter over
temperature value using the numeric keypad. Temperature appears on
display as it is being entered.
Pressing
←
or
→
on numeric keypad
moves the cursor to the left or right,
respectively.
Pressing RETURN saves the changed
cycle value and returns display to screen
#21.
36
CHANGE VALUES - OVER TEMP
RETURN
1
2
3
4
5
6
7
8
9
←
←
←
←
←
0
→
→
→
→
→
SET OVER TEMP
06.0 C
The over temp.
plus the control
temp. is the maximum sterilize
temp.
before an over temp.
alarm occurs.
If the alarm clears,
the sterilize time
will resume.
Pressing
←
or
→
on numeric keypad
moves the cursor to the left or right,
respectively.
Pressing RETURN saves the changed
cycle value and returns display to screen
#21.
Current
Programmed
Setting