30 Control panel
•
External
: The drive is in external control, ie, controlled through I/O or fieldbus.
The icons in the top pane indicate which actions are allowed with the control
panel:
2.
Panel bus:
Indicates that there are more than one drive connected to this panel.
To switch to another drive, go to
Options - Select drive
.
3.
Status icon
: Indicates the status of the drive and the motor. The direction of the
arrow indicates forward (clockwise) or reverse (counter-clockwise) rotation
4.
Drive name
: If a name has been given, it is displayed in the top pane. By default,
it is “ACQ580”. You can change the name on the control panel by selecting
Menu
- Primary settings - Clock, region, display
5.
Reference value
: Speed, frequency, etc. is shown with its unit. For information on
changing the reference value in the
Primary settings
menu (see page
6.
Content area
: The actual content of the view is displayed in this area. The
content varies from view to view. The example view on page
is the main view
of the control panel which is called the Home view.
7.
Softkey selections
: Displays the functions of the softkeys (
and
) in a
given context.
8.
Clock
: The clock displays the current time. You can change the time and time
format on the control panel by selecting
Menu - Primary settings - Clock,
region, display
(see page
).
You can adjust the display contrast and back light functionality on the control panel by
selecting
Menu - Primary settings - Clock, region, display
(see page
).
Text/Icons
Starting from this
control panel
Stopping from this
control panel
Giving reference
from this panel
Auto
Not allowed
Not allowed
Not allowed
Auto
Allowed
Allowed
Not allowed
Auto
Not allowed
Allowed
Allowed
Auto
Allowed
Allowed
Allowed
Status icon
Animation
Drive status
-
Stopped
-
Stopped, start inhibited
Blinking
Stopped, start command given but start inhibited. See
Menu - Diagnostics
on the control panel
Blinking
Faulted
Blinking
Running, at reference, but the reference value is 0
Rotating
Running, not at reference
Rotating
Running, at reference
Содержание ACQ580
Страница 1: ...ABB drives for water Firmware manual ACQ580 pump control program ...
Страница 4: ... 2017 ABB Oy All Rights Reserved 3AXD50000035867 Rev C EN EFFECTIVE 2017 06 21 ...
Страница 29: ...Start up control with I O and ID run 25 After the ID run is completed text Done is shown on row ID run ...
Страница 30: ...26 Start up control with I O and ID run ...
Страница 40: ...36 Default configuration ...
Страница 304: ...300 Parameters ...
Страница 340: ...336 Additional parameter data ...
Страница 422: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035867 Rev C EN 2017 06 21 3AXD50000035867C ...