Additional parameter data 311
22.74 Motor potentiometer down
source
-
-
1 = 1
22.75 Motor potentiometer ramp time
0.0…3600.0
s
10 = 1 s
22.76 Motor potentiometer min value
-32768.00…32767.00
-
100 = 1
22.77 Motor potentiometer max
value
-32768.00…32767.00
-
100 = 1
22.80 Motor potentiometer ref act
-32768.00…32767.00
-
100 = 1
22.86 Speed reference act 6
-30000.00…30000.00
rpm
100 = 1 rpm
22.87 Speed reference act 7
-30000.00…30000.00
rpm
100 = 1 rpm
23 Speed reference ramp
23.01 Speed ref ramp input
-30000.00…30000.00
rpm
100 = 1 rpm
23.02 Speed ref ramp output
-30000.00…30000.00
rpm
100 = 1 rpm
23.12 Acceleration time 1
0.000…1800.000
s
1000 = 1 s
23.13 Deceleration time 1
0.000…1800.000
s
1000 = 1 s
23.23 Emergency stop time
0.000…1800.000
s
1000 = 1 s
23.32 Shape time 1
0.000...1800.000
s
1000 = 1 s
24 Speed reference conditioning
24.01 Used speed reference
-30000.00…30000.00
rpm
100 = 1 rpm
24.02 Used speed feedback
-30000.00…30000.00
rpm
100 = 1 rpm
24.03 Speed error filtered
-30000.0…30000.0
rpm
100 = 1 rpm
24.04 Speed error inverted
-30000.0…30000.0
rpm
100 = 1 rpm
24.11 Speed correction
-10000.00…10000.00
rpm
100 = 1 rpm
24.12 Speed error filter time
0…10000
ms
1 = 1 ms
25 Speed control
25.01 Torque reference speed
control
-1600.0…1600.0
%
10 = 1%
25.02 Speed proportional gain
0.00…250.00
-
100 = 1
25.03 Speed integration time
0.00…1000.00
s
100 = 1 s
25.04 Speed derivation time
0.000…10.000
s
1000 = 1 s
25.05 Derivation filter time
0…10000
ms
1 = 1 ms
25.15 Proportional gain em stop
1.00…250.00
-
100 = 1
25.53 Torque prop reference
-30000.0…30000.0
%
10 = 1%
25.54 Torque integral reference
-30000.0…30000.0
%
10 = 1%
25.55 Torque deriv reference
-30000.0…30000.0
%
10 = 1%
28 Frequency reference chain
28.01 Frequency ref ramp input
-500.00…500.00
Hz
100 = 1 Hz
28.02 Frequency ref ramp output
-500.00…500.00
Hz
100 = 1 Hz
28.11 Ext1 frequency ref1
-
-
1 = 1
28.15 Ext2 frequency ref1
-
-
1 = 1
28.21 Constant frequency function
00b…11b
-
1 = 1
No.
Name
Type
Range
Unit
FbEq32
Содержание ACQ580
Страница 1: ...ABB drives for water Firmware manual ACQ580 pump control program ...
Страница 4: ... 2017 ABB Oy All Rights Reserved 3AXD50000035867 Rev C EN EFFECTIVE 2017 06 21 ...
Страница 29: ...Start up control with I O and ID run 25 After the ID run is completed text Done is shown on row ID run ...
Страница 30: ...26 Start up control with I O and ID run ...
Страница 40: ...36 Default configuration ...
Страница 304: ...300 Parameters ...
Страница 340: ...336 Additional parameter data ...
Страница 422: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035867 Rev C EN 2017 06 21 3AXD50000035867C ...