TROUBLESHOOTING
Page B9-4
Error
No.
Causes
Solutions
39 a. The Station No.7 transfer button was held down for 15
seconds or longer.
a. Clear the Error Code from memory.
b. The Station No.7 Control Head transfer button is
defective.
b. Replace the Control Head.
c. The Control Head Harness is miswired.
c. Ensure that the orange conductor is crimped to pin 4 at
both ends and the red wire is crimped to pin 5 at both
ends of the Harness.
d. The Control Head’s Pigtail is miswired.
d. Ensure that the orange conductor is crimped to pin 4 of
the connector and connected to pin 4 of the Control
Head’s terminal block. Ensure that the red conductor
is crimped to pin 5 of the connector and connected to
pin 3 of the Control Head’s terminal block.
40 a. The Station No.8 transfer button was held down for 15
seconds or longer.
a. Clear the Error Code from memory.
b. The Station No.8 Control Head transfer button is
defective.
b. Replace the Control Head.
c. The Control Head Harness is miswired.
c. Ensure that the orange conductor is crimped to pin 4 at
both ends and the red wire is crimped to pin 5 at both
ends of the Harness.
d. The Control Head’s Pigtail is miswired.
d. Ensure that the orange conductor is crimped to pin 4 of
the connector and connected to pin 4 of the Control
Head’s terminal block. Ensure that the red conductor
is crimped to pin 5 of the connector and connected to
pin 3 of the Control Head’s terminal block.
41 a. The Station No.9 transfer button was held down for 15
seconds or longer.
a. Clear the Error Code from memory.
b. The Station No.9 Control Head transfer button is
defective.
b. Replace the Control Head.
c. The Control Head Harness is miswired.
c. Ensure that the orange conductor is crimped to pin 4 at
both ends and the red wire is crimped to pin 5 at both
ends of the Harness.
d. The Control Head’s Pigtail is miswired.
d. Ensure that the orange conductor is crimped to pin 4 of
the connector and connected to pin 4 of the Control
Head’s terminal block. Ensure that the red conductor
is crimped to pin 5 of the connector and connected to
pin 3 of the Control Head’s terminal block.
42 a. The Station No.10 transfer button was held down for
15 seconds or longer.
a. Clear the Error Code from memory.
b. The Station No.10 Control Head transfer button is
defective.
b. Replace the Control Head.
c. The Control Head Harness is miswired.
c. Ensure that the orange conductor is crimped to pin 4 at
both ends and the red wire is crimped to pin 5 at both
ends of the Harness.
d. The Control Head’s Pigtail is miswired.
d. Ensure that the orange conductor is crimped to pin 4 of
the connector and connected to pin 4 of the Control
Head’s terminal block. Ensure that the red conductor
is crimped to pin 5 of the connector and connected to
pin 3 of the Control Head’s terminal block.
43 a. The Serial Harness is in excess of 120 feet (37m).
a. Reposition the Processor(s) so that the Serial Harness
is less than 120 feet (37m).
b. The Processor is defective.
b. Replace the faulty Processor.
c. The Serial Harness’s shield is not properly terminated. c. Ensure that the shield is terminated and the termina-
tion is at one side only.
44 a. The Serial Harness is in excess of 120 feet (37m).
a. Reposition the Processor(s) so that the Serial Harness
is less than 120 feet (37m).
b. The Processor is defective.
b. Replace the faulty Processor.
c. The Serial Harness’s shield is not properly terminated. c. Ensure that the shield is terminated and the termina-
tion is at one side only.
45 a. The Serial Harness is not connected at one or more
Processors.
a. Ensure that the Serial Harness is properly seated at all
Processors.
b. The Serial Harness is incorrectly wired.
b. Refer to the Serial Plug pin-out in Section Table B13-4:
page B13-2. Correct or replace the Harness.
c. Loss of power to one of the Processors.
c. Restore Power to the Processor.
Table B9-9: Basic Control System Problem Causes and Solutions
Summary of Contents for ClearCommand 9000 Series
Page 132: ......
Page 133: ...APPENDIX A...
Page 134: ......
Page 139: ......
Page 140: ...Page A 4...
Page 143: ......
Page 144: ...10...
Page 148: ...Page A 18...
Page 149: ...Page A 19 TEMPLATE...
Page 150: ...Page A 20...
Page 152: ...Page A 22...
Page 154: ...Page A 24...
Page 156: ...Page A 26...
Page 157: ...Page A 27 Drawing 11488D 1 Twin Screw Single APS Connection Alternate Remote Switch...
Page 158: ...Page A 28...
Page 159: ...Page A 29 Drawing 11488D 2 Twin Screw Dual APS Connections...
Page 160: ...Page A 30...
Page 161: ...Page A 31 Drawing 11488D 3 APS Notes Page...
Page 162: ...Page A 32...
Page 164: ...Page A 34...
Page 166: ...Page A 36...
Page 170: ...Page A 40...
Page 172: ...Page A 42...
Page 176: ...Page A 46...
Page 178: ...Page C 48 ZF Mathers LLC 12125 Harbour Reach Drive Suite B Mukilteo WA 98275...
Page 179: ...APPENDIX B...
Page 180: ......
Page 234: ...Appendix B 6...
Page 238: ...Appendix B 10...
Page 242: ...Appendix B 14...
Page 247: ...Service Field Test Unit Reference Manual MM13927 Rev E 4 07...
Page 248: ......
Page 250: ...Page ii Table of Contents...
Page 264: ...SERVICE FIELD TEST UNIT MM13927 RvD 10 03 Page 3 2...
Page 265: ...APPENDIX C...
Page 266: ......
Page 267: ...Appendix C 1 Drawing 12284A 1 ClearCommand Diagram all options...
Page 268: ...Appendix C 2...
Page 269: ...Appendix C 3 Drawing 12284A 2 ClearCommand Circuit Board Connections...
Page 270: ...Appendix C 4...
Page 271: ...Appendix C 5 Drawing 12284A 3 ClearCommand Drawing Notes Page...
Page 272: ...Appendix C 6...