TROUBLESHOOTING
PageB8-2
26
Station No.4
Faulted Low
Station No.4 Control Head’s lever position is out of range.
The input appears to be too low.
27
Station No.5
Faulted Low
Station No.5 Control Head’s lever position is out of range.
The input appears to be too low.
28
Station No.6
Faulted Low
Station No.6 Control Head’s lever position is out of range.
The input appears to be too low.
29
Station No.7
Faulted Low
Station No.7 Control Head’s lever position is out of range.
The input appears to be too low.
30
Station No.8
Faulted Low
Station No.8 Control Head’s lever position is out of range.
The input appears to be too low.
31
Station No.9
Faulted Low
Station No.9 Control Head’s lever position is out of range.
The input appears to be too low.
32
Station No.10
Faulted Low
Station No.10 Control Head’s lever position is out of range.
The input appears to be too low.
33
Station No.1
Button Stuck Closed
Station No.1 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
34
Station No.2
Button Stuck Closed
Station No.2 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
35
Station No.3
Button Stuck Closed
Station No.3 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
36
Station No.4
Button Stuck Closed
Station No.4 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
37
Station No.5
Button Stuck Closed
Station No.5 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
38
Station No.6
Button Stuck Closed
Station No.6 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
Error
No.
Title
Description
39
Station No.7
Button Stuck Closed
Station No.7 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
40
Station No.8
Button Stuck Closed
Station No.8 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
41
Station No.9
Button Stuck Closed
Station No.9 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
42
Station No.10
Button Stuck Closed
Station No.10 Control Head’s Transfer Button has either been closed too long or
has been closed since power-up.
43
CAN Communication
Stuffing Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is a stuffing error.
44
CAN Communication
Form Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is a form error.
45
CAN Communication
Acknowledge Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is an acknowledge error.
46
CAN Communication
Bit 1 Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is a Bit 1 error.
47
CAN Communication
Bit 0 Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is a Bit 0 error.
48
CAN Communication
CRC Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is a CRC error.
49
CAN Communication
Bus Error
The Control-Area-Network protocol has detected an error in communication
with other devices on the network. The error type is a Bus failure error. The
error cannot be recovered from without cycling power to the Processor.
50
Comm. Error Time-out
System 1
Communication with System 1 has been too long without a Refresh message.
51
Comm. Error Time-out
System 2
Communication with System 1 has been too long without a Refresh message.
52
Comm. Error Time-out
System 3
Communication with System 1 has been too long without a Refresh message.
53
Comm. Error Time-out
System 4
Communication with System 1 has been too long without a Refresh message.
54
Comm. Error Time-out
System 5
Communication with System 1 has been too long without a Refresh message.
55
SE Communication Error
Communication with the Station Expander has been too long without a Refresh
message.
56
High Battery Voltage Fault The applied battery voltage is 30VDC or higher for at least two seconds.
57
Low Battery Voltage Fault
The applied battery voltage is 10VDC or lower for at least two seconds.
58
Reset Due to Software
Watchdog
The system has had an unexpected Reset, due to a software/ hardware fault.
59
Reset Due to Software Fault The system has had an unexpected Reset, due to a software fault.
Table B8-6: Basic Control System Error Codes
Summary of Contents for ClearCommand 9000 Series
Page 132: ......
Page 133: ...APPENDIX A...
Page 134: ......
Page 139: ......
Page 140: ...Page A 4...
Page 143: ......
Page 144: ...10...
Page 148: ...Page A 18...
Page 149: ...Page A 19 TEMPLATE...
Page 150: ...Page A 20...
Page 152: ...Page A 22...
Page 154: ...Page A 24...
Page 156: ...Page A 26...
Page 157: ...Page A 27 Drawing 11488D 1 Twin Screw Single APS Connection Alternate Remote Switch...
Page 158: ...Page A 28...
Page 159: ...Page A 29 Drawing 11488D 2 Twin Screw Dual APS Connections...
Page 160: ...Page A 30...
Page 161: ...Page A 31 Drawing 11488D 3 APS Notes Page...
Page 162: ...Page A 32...
Page 164: ...Page A 34...
Page 166: ...Page A 36...
Page 170: ...Page A 40...
Page 172: ...Page A 42...
Page 176: ...Page A 46...
Page 178: ...Page C 48 ZF Mathers LLC 12125 Harbour Reach Drive Suite B Mukilteo WA 98275...
Page 179: ...APPENDIX B...
Page 180: ......
Page 234: ...Appendix B 6...
Page 238: ...Appendix B 10...
Page 242: ...Appendix B 14...
Page 247: ...Service Field Test Unit Reference Manual MM13927 Rev E 4 07...
Page 248: ......
Page 250: ...Page ii Table of Contents...
Page 264: ...SERVICE FIELD TEST UNIT MM13927 RvD 10 03 Page 3 2...
Page 265: ...APPENDIX C...
Page 266: ......
Page 267: ...Appendix C 1 Drawing 12284A 1 ClearCommand Diagram all options...
Page 268: ...Appendix C 2...
Page 269: ...Appendix C 3 Drawing 12284A 2 ClearCommand Circuit Board Connections...
Page 270: ...Appendix C 4...
Page 271: ...Appendix C 5 Drawing 12284A 3 ClearCommand Drawing Notes Page...
Page 272: ...Appendix C 6...