TROUBLESHOOTING
PageB5-3
A) Check the Processor’s Display for error messages. Most
likely, one of error messages
13
thru
32
will be shown. The
exact number shown depends on which remote station is
experiencing the problem and whether the command sig-
nal was too high or too low.
B) Enter the Diagnostic Menu as outlined in Section B4,
page B4-1.
C) Depress the Up or Down (Scroll) Push Button until the
appropriate Remote Station is displayed.
•
The Remote Station are identified by the position of the deci-
mal points.
• Station 1 has no decimal point after the first digit to the far
right. The remaining three digits all have decimal points.
• If the digit to the far left had no decimal point following it, but
the remaining three do, this would represent Station 4.
D) The examples in Figure B5-16: are shown with no Control
Heads connected to any Remote Stations. When a Control
Head is connected, the appropriate A/D (Analog/Digital)
value for the present position of the Control Head’s lever
will be shown, as in the examples below:
E) An A/D value of 910 or greater will generate an Error Code.
The code will be
13
to
22
(Control Head # Faulted High),
depending on which Station has the high Command Signal.
• If the A/D value is greater than 910, but less than 990, one of
the following may be the cause:
1. The Control Head’s potentiometer is out of calibration.
2. The potentiometer is defective.
In either case, it is recommended that the Control
Head is replaced.
S
TATION
1
S
TATION
4
S
TATION
2
S
TATION
5
S
TATION
3
Figure B5-16: Display Examples of Remote Stations
S
TATION
1
(N
EUTRAL
C
OMMANDED
)
S
TATION
4
(N
O
C
ONTROL
H
EAD
C
ONNECTED
)
S
TATION
2
(F
ULL
A
HEAD
C
OMMANDED
)
S
TATION
5
(N
EUTRAL
C
OMMANDED
)
S
TATION
3
(F
ULL
A
STERN
C
OMMANDED
)
Figure B5-17: Display Examples of Remote Stations A/D Value
Summary of Contents for ClearCommand 9000 Series
Page 132: ......
Page 133: ...APPENDIX A...
Page 134: ......
Page 139: ......
Page 140: ...Page A 4...
Page 143: ......
Page 144: ...10...
Page 148: ...Page A 18...
Page 149: ...Page A 19 TEMPLATE...
Page 150: ...Page A 20...
Page 152: ...Page A 22...
Page 154: ...Page A 24...
Page 156: ...Page A 26...
Page 157: ...Page A 27 Drawing 11488D 1 Twin Screw Single APS Connection Alternate Remote Switch...
Page 158: ...Page A 28...
Page 159: ...Page A 29 Drawing 11488D 2 Twin Screw Dual APS Connections...
Page 160: ...Page A 30...
Page 161: ...Page A 31 Drawing 11488D 3 APS Notes Page...
Page 162: ...Page A 32...
Page 164: ...Page A 34...
Page 166: ...Page A 36...
Page 170: ...Page A 40...
Page 172: ...Page A 42...
Page 176: ...Page A 46...
Page 178: ...Page C 48 ZF Mathers LLC 12125 Harbour Reach Drive Suite B Mukilteo WA 98275...
Page 179: ...APPENDIX B...
Page 180: ......
Page 234: ...Appendix B 6...
Page 238: ...Appendix B 10...
Page 242: ...Appendix B 14...
Page 247: ...Service Field Test Unit Reference Manual MM13927 Rev E 4 07...
Page 248: ......
Page 250: ...Page ii Table of Contents...
Page 264: ...SERVICE FIELD TEST UNIT MM13927 RvD 10 03 Page 3 2...
Page 265: ...APPENDIX C...
Page 266: ......
Page 267: ...Appendix C 1 Drawing 12284A 1 ClearCommand Diagram all options...
Page 268: ...Appendix C 2...
Page 269: ...Appendix C 3 Drawing 12284A 2 ClearCommand Circuit Board Connections...
Page 270: ...Appendix C 4...
Page 271: ...Appendix C 5 Drawing 12284A 3 ClearCommand Drawing Notes Page...
Page 272: ...Appendix C 6...