SPEC
ELECTRICAL
Model
RX10RTL, RX10RL, RX10RTRL, RX10RSL,
RX10GTL, RXW10L, RX10ML
Voltage
12 V
Ignition system:
Ignition timing (B.T.D.C.)
5° at 1,500 r/min
Advanced type
Digital type
Ignition coil:
Model/Manufacturer
F6T567/MITSUBISHI
Primary coil resistance
1.19 ~ 1.61
Ω
at 20°C (68°F)
Secondary coil resistance
8.5 ~ 11.5 k
Ω
at 20°C (68°F)
Charging system:
Type
AC magneto
Normal output
14 V/35 A at 5,000 r/min
DC-T.C.I:
Magneto model/Manufacturer
F4T47971/MITSUBISHI
Standard
14 V 35 A, 490 W at 5,000 r/min
Pickup coil resistance (color code)
446 ~ 545
Ω
at 20°C (68°F) (White/Red – White/Green)
Stator coil resistance (color code)
0.19 ~ 0.24
Ω
at 20°C (68°F) (White – White)
T.C.I unit model/Manufacturer
F8T83171/MITSUBISHI (RX10RTL, RX10RL,
RX10RTRL, RX10RSL, RX10GTL, RXW10L)
F8T83172/MITSUBISHI (RX10ML)
Rectifier/regulator:
Type
Short circuit type
Model/Manufacturer
FH001/SHINDENGEN
No load regulated voltage (DC)
14.1 ~ 14.9 V
Capacity (DC)
35 A
Withstand voltage
40 V
Battery:
Specific gravity
1.32
Manufacture
YUASA
Type
YTX14-BS 12V-12Ah
Ten hour rate amperage
12 A
Electric starter system:
Type
Constant mesh type
Starter motor:
Model/Manufacturer
8FP1/MORIC
Output
12 V - 0.95 kW
Armature coil resistance
Continuity check
0.008 ~ 0.010
Ω
at 20°C (68°C)
Insulation check
More than 100 k
Ω
at 20°C (68°F)
Brush
Overall length
9.8 mm (0.39 in)
Wear limit
5 mm (0.20 in)
Spring pressure
7.36 ~ 11.04 N (736 ~ 1,104 g, 26.0 ~ 38.9 oz)
Commutator diameter
28.5 mm (1.12 in)
Wear limit
27.5 mm (1.08 in)
Mica undercut
1.5 mm (0.059 in)
MAINTENANCE SPECIFICATIONS
125
Summary of Contents for RX10RTL
Page 2: ......
Page 8: ......
Page 21: ......
Page 25: ......
Page 29: ......
Page 141: ......
Page 259: ......
Page 265: ...SPEC 113 ...
Page 289: ...SPEC 113 ...
Page 313: ...SPEC 113 ...
Page 334: ...SPEC CABLE ROUTING CHEMINEMENT DES CABLES KABELDRAGNINGSSCHEMA CABLE ROUTING 134 ...
Page 336: ...SPEC CABLE ROUTING 136 ...
Page 338: ...SPEC CABLE ROUTING 138 ...
Page 340: ...SPEC CABLE ROUTING 140 ...
Page 342: ...SPEC CABLE ROUTING 142 ...
Page 344: ...SPEC CABLE ROUTING 144 ...
Page 346: ...SPEC CABLE ROUTING 146 ...
Page 348: ...SPEC CABLE ROUTING 148 ...
Page 350: ......
Page 351: ......
Page 352: ...2005 07 E F Sw ITP ...