FI
Fault code No.
Er-1
Symptom
No signal are received from the ECU.
Er-2
Symptom
No signal are received from the ECU within the specified duration.
Er-3
Symptom
Data from the ECU cannot be received correctly.
Er-4
Symptom
Non-registered data has been received from the meter.
Used diagnostic code No. – –
Order Inspection operation item and probable
cause
Operation item and countermeasure
Reinstatement
method
1
Connected condition of connector
Inspect the coupler for any pins that
may have pulled out.
Check the locking condition of the
coupler.
If there is a malfunction, repair it and connect it
securely.
Cylinder identification sensor coupler
Main wiring harness ECU coupler
Sub-wire harness coupler
Reinstated by
turning the main
switch ON.
2
Open or short circuit in wiring harness
and/or sub lead.
Repair or replace if there is an open or short circuit.
Between sensor coupler and ECU coupler
Yellow/Blue – Yellow/Blue
Black/White – Black/White
3
Malfunction in meter
Replace the meter.
4
Malfunction in ECU
Replace the ECU.
84
FUEL INJECTION SYSTEM
Summary of Contents for RX10RTL
Page 2: ......
Page 8: ......
Page 21: ......
Page 25: ......
Page 29: ......
Page 141: ......
Page 259: ......
Page 265: ...SPEC 113 ...
Page 289: ...SPEC 113 ...
Page 313: ...SPEC 113 ...
Page 334: ...SPEC CABLE ROUTING CHEMINEMENT DES CABLES KABELDRAGNINGSSCHEMA CABLE ROUTING 134 ...
Page 336: ...SPEC CABLE ROUTING 136 ...
Page 338: ...SPEC CABLE ROUTING 138 ...
Page 340: ...SPEC CABLE ROUTING 140 ...
Page 342: ...SPEC CABLE ROUTING 142 ...
Page 344: ...SPEC CABLE ROUTING 144 ...
Page 346: ...SPEC CABLE ROUTING 146 ...
Page 348: ...SPEC CABLE ROUTING 148 ...
Page 350: ......
Page 351: ......
Page 352: ...2005 07 E F Sw ITP ...