4.1 Establishing Database Administrator Password
The DX-80 system allows you to set up and maintain the system database using any DX-80 DET telephone, once
you have entered the database administrator password.
Note
: While it is possible to program the DX-80 system
while the telephone is in use, certain button operations are used during programming and cannot be used for tele-
phone call processing. Therefore, it is suggested that you not use these features simultaneously unless you have
been directed to do so by Vertical Technical Support.
The database administration password is by default set to
########
(eight #s) when programming by phone, and “
“ (eight spaces) when programming using PC-DBA. To change the default password, you must first connect to the
switch enter and Database Administration using the default password.
Passwords must be eight alphanumeric characters long. You can use any combination of letters and/or numbers,
plus the # symbol. Passwords are case-sensitive, so for example if you use a capital “R” you cannot enter a lower
case “r” when entering the password later.
4.1.1 PROGRAMMING USING THE DET
Note:
chg
,
bksp
,
save
,
one
,
always
,
del
, and
ack
are interactive LCD button operations. Use the three buttons
below the LCD display to actuate the associated operation.
1. Enter Database Administration using the feature code
Feature # *
and then enter the DB Admin password.
For details on how to enter numbers, upper case letters and lower case letters, see the tables in Section 4.18,
Setting Up Letter Type (Enhanced Lettering Scheme)
.
2. Press
show
. The system displays the DB Item Select screen.
Note: All database programming items are
indexed for fast access.
3. Enter
04-01
, then press
save
. The system advances you to the System Resources – DB PSWD screen and
displays the current password. The default is “########” (eight #s).
4. Press
chg
to change the password.
5. Enter the new eight-character, alphanumeric password and press
save
. Use the volume up or down buttons
to return to the DB Item Select screen.
6. To exit Database Administration press the
ON/OFF
button twice. Or, lift and replace the handset in the
hook-switch cradle.
4.1.2 PROGRAMMING USING PC-DBA
Before changing the database administrator password, you must first connect your laptop to the system. For details
on connecting, see Section 2.1.4.5,
.
1. Select
Programming
from the PC-DBA menu and press
Enter
. The system displays the Database Program-
ming menu.
2. Use the arrow keys to highlight
KSU DB Password
and press
Enter
. The system prompts you to enter the
old password.
Summary of Contents for Comdial DX-80
Page 1: ...Programming Manual Technical Manual Volume II GCA60 001 RB1105 ...
Page 4: ... iv This Page Intentionally Left Blank ...
Page 18: ...This page intentionally left blank ...
Page 58: ...GETTING STARTED SHORTCUTS TO HELP YOU WORK FASTER DX 80 Programming Manual 58 ...
Page 291: ... 291 A WORKSHEETS Worksheets DX 80 Programming Manual ...
Page 292: ...APPENDIX A DX 80 Programming Manual 292 ...
Page 293: ... 293 DX 80 Programming Manual APPENDIX A ...
Page 294: ...APPENDIX A DX 80 Programming Manual 294 ...
Page 295: ... 295 DX 80 Programming Manual APPENDIX A ...
Page 296: ...APPENDIX A DX 80 Programming Manual 296 ...
Page 297: ... 297 DX 80 Programming Manual APPENDIX A ...
Page 298: ...APPENDIX A DX 80 Programming Manual 298 ...
Page 299: ... 299 DX 80 Programming Manual APPENDIX A ...
Page 300: ...APPENDIX A DX 80 Programming Manual 300 ...
Page 301: ... 301 DX 80 Programming Manual APPENDIX A ...
Page 302: ...APPENDIX A DX 80 Programming Manual 302 ...
Page 303: ... 303 DX 80 Programming Manual APPENDIX A ...
Page 304: ...APPENDIX A DX 80 Programming Manual 304 ...
Page 308: ...APPENDIX B DX 80 Programming Manual 308 This Page Intentionally Left Blank ...
Page 321: ... 321 DX 80 Programming Manual INDEX This page intentionally left blank ...