- 157 -
DX-80 Programming Manual
P
ROGRAMMING
C
ALL
H
ANDLING
> S
ETTING
U
P
T
RANSFER
R
ECALLS
FOR
I
DLE
The following conditions apply to setting the transfer recall time.
• Extension users can transfer CO line calls and intercom calls.
• The system places transferred CO lines that recall on system hold.
• When transferring CO line recalls, the system displays the line number and extension number from where the
call was transferred.
• The transferred party will hear ring-back tone while the call is transfer ringing.
• In a screened transfer, if the destination extension answers the intercom call in voice announce hands-free
mode and does not go off hook, the system rings the destination extension.
• In screened transfer, if the destination extension answers the intercom call by lifting the handset, the system
immediately connects the caller to the destination extension.
• The system does not direct recalls to the programmed Alternate Attendant extension.
Other features whose programming may be affected by transfer recall time include the following.
• Transfer and Answer Call
• Recall
• Call Forward
• Forced Intercom Tone Ring
• Call Park / Call Park Answer
6.10.1 PROGRAMMING USING THE DET
Note:
chg
,
bksp
,
save
,
one
,
always
,
del
, and
ack
are interactive LCD button operations. Use the three buttons
below the LCD display to actuate the associated operation.
1. Enter Database Administration using the feature code
Feature # *
and then enter the DB Admin password.
2. Press
show
. The system displays the DB Item Select screen.
3. Enter
03-10
, then press save. This advances you to the Transfer-Idle Recall programming screen.
4. Press
chg
to select how long you want the system to ring the idle extension before pulling the call back.
Valid options include 16, 30, 60, 90, and 120 seconds. The default is 30 seconds.
5. Press
next
to advance to the next data item.
6. Enter
03-11
, then press
save
. This advances you to the Transfer-Busy Recall programming screen.
7. Press
chg
to select how long you want the system to ring the busy extension before pulling the call back.
Valid options include 16, 30, 60, 90, and 120 seconds. The default is 60 seconds.
8. Press the
Hold
button to return to the previous menu level,
Or, press the
Volume
button (up or down) to return to the DB Item Selection screen,
Or, exit programming.
Summary of Contents for Comdial DX-80
Page 1: ...Programming Manual Technical Manual Volume II GCA60 001 RB1105 ...
Page 4: ... iv This Page Intentionally Left Blank ...
Page 18: ...This page intentionally left blank ...
Page 58: ...GETTING STARTED SHORTCUTS TO HELP YOU WORK FASTER DX 80 Programming Manual 58 ...
Page 291: ... 291 A WORKSHEETS Worksheets DX 80 Programming Manual ...
Page 292: ...APPENDIX A DX 80 Programming Manual 292 ...
Page 293: ... 293 DX 80 Programming Manual APPENDIX A ...
Page 294: ...APPENDIX A DX 80 Programming Manual 294 ...
Page 295: ... 295 DX 80 Programming Manual APPENDIX A ...
Page 296: ...APPENDIX A DX 80 Programming Manual 296 ...
Page 297: ... 297 DX 80 Programming Manual APPENDIX A ...
Page 298: ...APPENDIX A DX 80 Programming Manual 298 ...
Page 299: ... 299 DX 80 Programming Manual APPENDIX A ...
Page 300: ...APPENDIX A DX 80 Programming Manual 300 ...
Page 301: ... 301 DX 80 Programming Manual APPENDIX A ...
Page 302: ...APPENDIX A DX 80 Programming Manual 302 ...
Page 303: ... 303 DX 80 Programming Manual APPENDIX A ...
Page 304: ...APPENDIX A DX 80 Programming Manual 304 ...
Page 308: ...APPENDIX B DX 80 Programming Manual 308 This Page Intentionally Left Blank ...
Page 321: ... 321 DX 80 Programming Manual INDEX This page intentionally left blank ...