P
ROGRAMMING
C
ALL
H
ANDLING
> P
ROGRAMMING
A
UTO
R
EDIAL
DX-80 Programming Manual
- 166 -
6.14.2 PROGRAMMING USING PC-DBA
1. Select
Programming
from the PC-DBA menu and press
Enter
. The system displays the Database Program-
ming menu.
2. Use the arrow keys to highlight
Call Handling
and press
Enter
. The system displays the Call Handling
menu.
3. Highlight
Category 2
and press
Enter
. The system displays the Call Handling—Category 2 menu.
4. Highlight
SLT Hook Flash – Start
and press
Enter
to set the Start range setting. This timer indicates the
minimum time that an analog/SLT must flash the hook-switch to be considered a valid flash-hook request.
A hook-flash that is shorter than this timer is considered a mistake; no action is taken. Valid options include
from 60 - 1400 milliseconds. The default is 200 milliseconds.
5. Highlight
SLT Hook Flash – End
and press
Enter
to set the End range setting. This timer indicates the max-
imum time that an analog/SLT must flash the hook-switch to be considered a valid flash-hook request. A
hook-flash that is longer than this timer is considered a hang up. Valid options include from 100 - 1500 mil-
liseconds. The default is 1000 milliseconds.
6. When you are done, press
Esc
to return to the Database Programming screen. The system prompts: “Exit
This Feature?”; press
Y
for yes.
7. The system prompts “Save Current Setting?” Press
Y
to save your changes.
8. The system then prompts “File Exists, Override?” Press
Y
to continue with the save operation.
9. Press
Esc
to return to the Database Programming menu.
10. When you have finished all programming changes, perform a Send operation to copy your new database to
the DX-80 switch system memory. For more details, see Section 2.1.4.4,
6.15 Programming Auto Redial
Extension users can use Automatic Redial (AR) to redial the last number dialed. The system automatically dials
the number and then waits for a predetermined time period. Following this predetermined time period if no action
is taken, the system hangs up and the redial cycle continues until it reaches the number of attempts you specify.
The following conditions apply to automatic redial.
Summary of Contents for Comdial DX-80
Page 1: ...Programming Manual Technical Manual Volume II GCA60 001 RB1105 ...
Page 4: ... iv This Page Intentionally Left Blank ...
Page 18: ...This page intentionally left blank ...
Page 58: ...GETTING STARTED SHORTCUTS TO HELP YOU WORK FASTER DX 80 Programming Manual 58 ...
Page 291: ... 291 A WORKSHEETS Worksheets DX 80 Programming Manual ...
Page 292: ...APPENDIX A DX 80 Programming Manual 292 ...
Page 293: ... 293 DX 80 Programming Manual APPENDIX A ...
Page 294: ...APPENDIX A DX 80 Programming Manual 294 ...
Page 295: ... 295 DX 80 Programming Manual APPENDIX A ...
Page 296: ...APPENDIX A DX 80 Programming Manual 296 ...
Page 297: ... 297 DX 80 Programming Manual APPENDIX A ...
Page 298: ...APPENDIX A DX 80 Programming Manual 298 ...
Page 299: ... 299 DX 80 Programming Manual APPENDIX A ...
Page 300: ...APPENDIX A DX 80 Programming Manual 300 ...
Page 301: ... 301 DX 80 Programming Manual APPENDIX A ...
Page 302: ...APPENDIX A DX 80 Programming Manual 302 ...
Page 303: ... 303 DX 80 Programming Manual APPENDIX A ...
Page 304: ...APPENDIX A DX 80 Programming Manual 304 ...
Page 308: ...APPENDIX B DX 80 Programming Manual 308 This Page Intentionally Left Blank ...
Page 321: ... 321 DX 80 Programming Manual INDEX This page intentionally left blank ...