Operation
3-26 Operation
Thermo Fisher Scientific
REC 4132 Rev
E
Use the following steps to configure outputs.
1.
Select
M
ORE
M
ENUS
/S
ETUP
/I/O/O
UTPUT
The following screen displays:
A96330
Figure 3–25.
Output Setup
EXAMPLE 1.
In
Figure 3–25
Output 1 is assigned Reject Device
that indicates this output is activated when a product is
rejected.
▲
2.
There are 10 output assignments (
Figure 3–26
)
•
Unassigned –
the output has no assignment
•
Reject Device –
activates when a package has been rejected
•
Alarm – turns on an output when there is an alarm
•
Shutdown –
turns on an output when there is a shutdown
•
X-ray Status –
activates current state of
X-ray
s, active when
X-
ray
s are on or imminent.