EZx Menus
Thermo Fisher Scientific
EZx Menus
A-41
REC 4132
Rev E
Path:
More Menus/New Product or Edit Product/Reject Setup
The
P
RODUCT
R
EJECT
setup determines the
Distance
(how far the
rejecter is from the X-ray),
Duration
(how long the signal to the reject
device should be on).
Reject Setup Screen
Figure A–39.
Product Reject Setup
The
TEST REJECTER
button allows the user to pass packages through
the system and the EZx rejects them allow the user to verify the rejecter
settings.
Note.
When the rejecter test mode is active, the button
background is blue.
▲
Reject Setup