Figure 1-6. Flash Status Register (FSTATUS)
15
9
8
Reserved
3VSTAT
R-0
R/W1C-0
7
4
3
2
1
0
Reserved
ACTIVEWAITS
STDBYWAITS
PWRS
R-0
R-0
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; W1C = Write 1 to clear; -
n
= value after reset
Table 1-4. Flash Status Register (FSTATUS) Field Descriptions
Bit
Field
Value
Description
15-9
Reserved
Any writes to these bits must always have a value of 0.
8
3VSTAT
Flash Voltage (V
DD3VFL
) Status Latch Bit. When set, this bit indicates that the 3VSTAT signal from
the pump module went to a high level. This signal indicates that the Flash 3.3-V supply went out of
the allowable range.
0
Writes of 0 are ignored.
1
When this bit reads 1, it indicates that the Flash 3.3-V supply went out of the allowable range.
Clear this bit by writing a 1.
7-4
Reserved
Any writes to these bits must always have a value of 0.
3
ACTIVEWAITS
Bank and Pump Standby To Active Wait Counter Status Bit. This bit indicates whether the
respective wait counter is timing out an access.
0
The counter is not counting.
1
The counter is counting.
2
STDBYWAITS
Bank and Pump Sleep To Standby Wait Counter Status Bit. This bit indicates whether the
respective wait counter is timing out an access.
0
The counter is not counting.
1
The counter is counting.
1-0
PWRS
Power Modes Status Bits. These bits indicate which power mode the Flash/OTP is currently in.
The PWRS bits are set to the new power mode only after the appropriate timing delays have
expired.
00
Pump and bank in sleep mode (lowest power)
01
Pump and bank in standby mode
10
Reserved
11
Pump and bank active and in read mode (highest power)
(1)
This register is EALLOW protected. See
for more information.
(2)
This register is protected by the Code Security Module (CSM). See
for more information.
System Control and Interrupts