Table 3-51. Event-Trigger Prescale Register (ETPS) Field Descriptions (continued)
Bits
Name
Description
11-10
SOCACNT
ePWM ADC Start-of-Conversion A Event (EPWMxSOCA) Counter Register
These bits indicate how many selected ETSEL[SOCASEL] events have occurred:
00
No events have occurred.
01
1 event has occurred.
10
2 events have occurred.
11
3 events have occurred.
9-8
SOCAPRD
ePWM ADC Start-of-Conversion A Event (EPWMxSOCA) Period Select
These bits determine how many selected ETSEL[SOCASEL] events need to occur before an
EPWMxSOCA pulse is generated. To be generated, the pulse must be enabled (ETSEL[SOCAEN]
= 1). The SOCA pulse will be generated even if the status flag is set from a previous start of
conversion (ETFLG[SOCA] = 1). Once the SOCA pulse is generated, the ETPS[SOCACNT] bits
will automatically be cleared.
00
Disable the SOCA event counter. No EPWMxSOCA pulse will be generated
01
Generate the EPWMxSOCA pulse on the first event: ETPS[SOCACNT] = 0,1
10
Generate the EPWMxSOCA pulse on the second event: ETPS[SOCACNT] = 1,0
11
Generate the EPWMxSOCA pulse on the third event: ETPS[SOCACNT] = 1,1
7-4
Reserved
Reserved
3-2
INTCNT
ePWM Interrupt Event (EPWMx_INT) Counter Register
These bits indicate how many selected ETSEL[INTSEL] events have occurred. These bits are
automatically cleared when an interrupt pulse is generated. If interrupts are disabled, ETSEL[INT] =
0 or the interrupt flag is set, ETFLG[INT] = 1, the counter will stop counting events when it reaches
the period value ETPS[INTCNT] = ETPS[INTPRD].
00
No events have occurred.
01
1 event has occurred.
10
2 events have occurred.
11
3 events have occurred.
1-0
INTPRD
ePWM Interrupt (EPWMx_INT) Period Select
These bits determine how many selected ETSEL[INTSEL] events need to occur before an interrupt
is generated. To be generated, the interrupt must be enabled (ETSEL[INT] = 1). If the interrupt
status flag is set from a previous interrupt (ETFLG[INT] = 1) then no interrupt will be generated until
the flag is cleared via the ETCLR[INT] bit. This allows for one interrupt to be pending while another
is still being serviced. Once the interrupt is generated, the ETPS[INTCNT] bits will automatically be
cleared.
Writing a INTPRD value that is the same as the current counter value will trigger an interrupt if it is
enabled and the status flag is clear.
Writing a INTPRD value that is less than the current counter value will result in an undefined state.
If a counter event occurs at the same instant as a new zero or non-zero INTPRD value is written,
the counter is incremented.
00
Disable the interrupt event counter. No interrupt will be generated and ETFRC[INT] is ignored.
01
Generate an interrupt on the first event INTCNT = 01 (first event)
10
Generate interrupt on ETPS[INTCNT] = 1,0 (second event)
11
Generate interrupt on ETPS[INTCNT] = 1,1 (third event)
Enhanced Pulse Width Modulator (ePWM) Module
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
TMS320x2806x Microcontrollers
361