Table 14-12. I2C Status Register (I2CSTR) Field Descriptions (continued)
Bit
Field
Type
Reset
Description
4
XRDY
R
1h
Transmit-data-ready interrupt flag bit.
When not in FIFO mode, XRDY indicates that the data transmit
register (I2CDXR) is ready to accept new data because the previous
data has been copied from I2CDXR to the transmit shift register
(I2CXSR). The CPU can poll XRDY or use the XRDY interrupt
request When in FIFO mode, use TXFFINT instead.
Reset type: SYSRSn
0h (R/W) = I2CDXR not ready. XRDY is cleared when data is written
to I2CDXR.
1h (R/W) = I2CDXR ready: Data has been copied from I2CDXR to
I2CXSR.
XRDY is also forced to 1 when the I2C module is reset.
3
RRDY
R/W1C
0h
Receive-data-ready interrupt flag bit.
When not in FIFO mode, RRDY indicates that the data receive
register (I2CDRR) is ready to be read because data has been copied
from the receive shift register (I2CRSR) to I2CDRR. The CPU can
poll RRDY or use the RRDY interrupt request When in FIFO mode,
use RXFFINT instead.
Reset type: SYSRSn
0h (R/W) = I2CDRR not ready. RRDY is cleared by any one of the
following events:
- I2CDRR is read by the CPU. Debug probe reads of the I2CDRR do
not affect this bit.
- RRDY is manually cleared. To clear this bit, write a 1 to it.
- The I2C module is reset.
1h (R/W) = I2CDRR ready: Data has been copied from I2CRSR to
I2CDRR.
2
ARDY
R/W1C
0h
Register-access-ready interrupt flag bit (only applicable when the I2C
module is in the master
mode).
ARDY indicates that the I2C module registers are ready to be
accessed because the previously programmed address, data, and
command values have been used. The CPU can poll ARDY or use
the ARDY interrupt request.
Reset type: SYSRSn
0h (R/W) = The registers are not ready to be accessed. ARDY is
cleared by any one of the following events:
- The I2C module starts using the current register contents.
- ARDY is manually cleared. To clear this bit, write a 1 to it.
- The I2C module is reset.
1h (R/W) = The registers are ready to be accessed.
In the nonrepeat mode (RM = 0 in I2CMDR): If STP = 0 in I2CMDR,
the ARDY bit is set when the internal data counter counts down to 0.
If STP = 1, ARDY is not affected (instead, the I2C module generates
a STOP condition when the counter reaches 0).
In the repeat mode (RM = 1): ARDY is set at the end of each byte
transmitted from I2CDXR.
Inter-Integrated Circuit Module (I2C)
860
TMS320x2806x Microcontrollers
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022