4-248
Example2:
S1~S8, R1, R2 and DO1 are OFF
0
0
0
0
0
0
0 0
Input Terminal(S8)
Input Terminal(S7)
Input Terminal(S6)
Input Terminal(S5)
Input Terminal(S4)
Input Terminal(S3)
Input Terminal(S2)
Input Terminal(S1)
0: OPEN
1: CLOSE
0
0
0
Output Terminal(DO1)
Output Terminal(R2)
Output Terminal(R1)
Note:
Refer to section 4.3 for monitors 12-11~12-64.
Monitoring parameter12-66:
Encoder Angle
Encoder PG pulse (20-27) is set to correct connection with the encoder wiring. Make the motor rotate forwardly at
non-run state and the angle will accumulate to 360
°
at two times; if make the motor rotate reversely, the angle will
regress to 360
°
at two times.
Monitoring parameter 12-67:
Cumulative Energy (KWHr)
& 12-68:
Cumulative Energy (MWHr)
Initialization of Cumulative Energy of 11-54 can clear these monitoring parameters.
Monitoring parameter 12-38:
PID setting
& 12-39:
PID Feedback
Refer to the setting of 10-33~10-35.
Monitoring parameter 12-76:
No-Load Voltage Output
It is required to be with the descriptions of parameter 02-09 (excitation current of motor 1) and parameter 17-09
(motor excitation current).
Monitoring parameter 12-78:
Z-Phase Bias Value
It is required to be with the parameter 21-43 (Offset Angle).
Monitoring parameter 12-79:
Pulse Input Percentage
Refer to parameter 03-30 (Selection of pulse input)
Note: It can perform run command when viewing monitoring parameters (12-05~12-79).