4-251
13-08=3:
3-wire initialization (230V/460V/690V)
Multi-function digital input terminal S7 controls the forward / reverse direction, and terminals S1 and S2 are set for
3-wire start operation and stop command.
Refer to Figure 4.4.2 and Figure 4.4.3 for 3-wire type operation mode.
Inverter input voltage (01-14) is automatically set to 220V (200V class) or 440V (400V class)
13-08=4:
2-wire initialization (230V/415V)
Multi-function digital input terminal S1 controls forward operation / stop command, and S2 controls reverse
operation / stop command. Refer to Figure 4.4.1.
Inverter input voltage (01-14) is automatically set to 220V (200V class) or 440V (400V class)
13-08=5:
3-wire initialization (230V/415V)
Multi-function digital input terminal S5 controls the forward / reverse direction, and terminals S1 and S2 are set for
3-wire start operation and stop command.
Inverter input voltage (01-14) is automatically set to 220V (200V class) or 440V (400V class)