4-17
Group 01: V/F Control Parameters
Code Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
Motor 2
575V: 0.0~670.0
575.0
690V: 0.0~804.0
690.0
01-26
V/F Curve
Selection of
Motor 2
0~FF
F
-
O
X
X
X
X
X
X
*3
*: Refer to the attachment 1.
Group 02: IM Motor Parameters
Code Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
02-00
No-Load Current
of Motor1
0.01~600.00
-
A
O
X
X
X
X
X
O
02-01
Rated Current of
Motor1
Modes of V/F, V/F+PG
are
10%~200% of
inverter’s rated current.
Modes of SLV, SV are
25%~200%
of inverter’s
rated current.
-
A
O
O
O
O
X
X
O
02-02
Reserved
02-03
Rated Rotation
Speed of Motor1
0~60000
-
Rpm O
O
O
O
X
X
O
02-04
Rated Voltage of
Motor1
230V: 50.0~240.0
220.0
V
O
O
O
O
X
X
O
460V: 100.0~480.0
440.0
575V: 150.0~670.0
575.0
690V: 200.0~804.0
690.0
02-05
Rated Power of
Motor1
0.01~600.00
-
kW
O
O
O
O
X
X
O
02-06
Rated Frequency
of Motor1
5.0~599.0
60.0
Hz
O
O
O
O
X
X
O
02-07 Poles of Motor 1 2~16(Even)
4
-
O
O
O
O
X
X
O
02-08
Reserved
02-09
Excitation Current
of Motor 1
15%~70% of Motor
Rated Current
-
%
X
X
O
O
X
X
X
02-10
Core Saturation
Coefficient 1
of Motor 1
1~100
-
%
X
X
O
O
X
X
X
02-11
Core Saturation
Coefficient 2
of Motor 1
1~100
-
%
X
X
O
O
X
X
X
02-12
Core Saturation
Coefficient 3
of Motor 1
80~300
-
%
X
X
O
O
X
X
X