Wiring Example:
Figure 4.4.17 and 4.4.18 show an example of a 9-speed operation selection.
S1 Forward Run / Stop (03-00 = 0)
S2 Reverse Run / Stop (03-01 = 1)
24VG
S3 External Fault (03-02 = 25)
S4 Fault Reset (03-03 = 17)
S5 Multi-Step Speed Ref 1 (03-04=2)
S6 Multi-Step Speed Ref 2 (03-05=3)
S7 Multi-Step Speed Ref 3 (03-06=4)
S8 Jog Frequency Reference (03-07=29)
Figure 4.4.17 Control Terminal Wiring Example
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
Termina
l
(S1)
(S5)
(S6)
(S7)
(S8)
Forward RUN
Multi- step
speed Ref 1
Multi- step
speed Ref 2
Multi- step
speed Ref 3
JOG Frequency
Ref
speed
1
speed
2
speed
3
speed
4
speed
5
speed
6
speed
7
speed
8
speed
9
*1
master
speed
ref
*2
aux.
speed
ref
t
t
t
t
t
t
Frequency
Reference
(05-01)
(00-18)
(05-02)
(05-03)
(05-04)
(05-05)
(05-06)
(05-07)
(05-08)
Figure 4.4.18: 9-speed timing diagram
*1. When 00-05=1, multi-speed frequency reference is set by analog input AI1 or AI2. When 00-05=0,
multi-speed frequency reference is set by 05-01.
*2. When 04-05=0, multi-speed frequency reference is set by Auxiliary frequency (AI2). When 04-05
≠0,
multi-speed frequency reference is set by 05-02.