![TECO-Westinghouse A510 Instruction Manual Download Page 349](http://html.mh-extra.com/html/teco-westinghouse/a510/a510_instruction-manual_1072531349.webp)
4-274
20-Speed Control Parameters
20-00
ASR gain 1
Range
0.00~250.00
20-01
ASR integral time 1
Range
0.001~10.000 Sec
20-02
ASR gain 2
Range
0.00~250.00
20-03
ASR integral time 2
Range
0.001~10.000 Sec
20-04
ASR integral time limit
Range
0~300
%
20-05
ASR positive limit
Range
0.1 ~ 10 %
20-06
ASR negative limit
Range
0.1 ~ 1 %
20-07
Selection of acceleration and deceleration of P/PI
Range
0:
PI speed control will be enabled only in constant speed.
For the speed acceleration and deceleration, only use P control.
1:
Speed control is enabled either in acceleration or deceleration.
20-08
ASR delay time
Range
0.000~0.500 Sec
20-09
Speed Observer Proportional(P) Gain1
Range
0.00~2.55
20-10
Speed Observer Integral(I) Time 1
Range
0.01~10.00 Sec
20-11
Speed Observer Proportional(P) Gain2
Range
0.00~2.55
20-12
Speed Observer Integral(I) Time 2
Range
0.01~10.00 Sec
20-13
Low-pass filter Time constant of speed feedback 1
Range
1~1000 msec
20-14
Low-pass filter Time constant of speed feedback 2
Range
1~1000 msec