![TECO-Westinghouse A510 Instruction Manual Download Page 136](http://html.mh-extra.com/html/teco-westinghouse/a510/a510_instruction-manual_1072531136.webp)
4-61
8:
Motor’s acceleration
error
9: Warning
17-12
Proportion of
Motor Leakage
Inductance
0.1~15.0
3.4
%
X
X
O
O
X
X
X
17-13
Motor Slip
Frequency
0.10~20.00
1.00
Hz
X
X
O
O
X
X
X
17-14
Selection of
Rotation
Auto-tuning
0:VF Rotation Auto-tuning
1: Vector Rotation
Auto-tuning
0
-
O
O
O
O
X
X
O
KVA: The default value of this parameter will be changed by different capacities of inverter.
*: The default value is 1 in VF/ VF+PG mode while the default value is 0 in SLV/ SV/ SLV2 mode.
*: It is suggested that HD/ ND mode (00-27) and application presets (00-32) be selected first before motor
performs auto-tuning.
Note: The value of mode selection of automatic tuning is 6 (Static Auto-tuning Combination).When do
auto-tuning with no-load motor, it suggest select 17-00=5 (Rotation Auto-tuning Combination)