GPS Input Module Default Settings
426
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
MTIE Limits for the E1 Input Module
provides MTIE limits for the E1 Input Module configuration settings and
factory defaults and ranges.
GPS Input Module Default Settings
The GPS Input Module maintains factory default and current user configuration
settings. The configuration settings for the GPS Input Module are provided in
Table E-6. E1 Input Module – MTIE Limits
Time
(seconds)
Set Limit L1
(ns)
Set Limit L2
(ns)
Clear Limit L1
(ns)
Clear Limit L2
(ns)
10
80
100
70
90
100
800
1000
700
900
1000
1600
2000
1400
1800
10000
1170
2835
2000
2500
100000
4260
5330
3800
4800
Table E-7. GPS Input Module Default Configuration Settings
Configuration Setting
Factory Default
Range
Position (GPS only)
Latitude (+ = North, – = South)
Longitude (+ = East, – = West)
Height
Averages
PDOP
Pos Mode
0
0
0
300
0
Calc
±
90 degrees
±
180 degrees
–60 to 4,000 meters
10 to 3600
1 to 10
User/Calc
Min Elevation for position
5
0 to 50 degrees
Min PDOP for position
3
1 to 10
Min Elevation for timing
10
0 to 50 degrees
Module Status
Enabled
Enabled
Disabled
Priority
0
0 to 10
Sigma limit
25
10 to 1000 US
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...