12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 191
Output Module Reference Data
E1/2048 kHz Output Module
E1/2048 kHz Output Signal Specifications
Specifications for the E1/2048 kHz Output signals are provided in
SOURCE B
Green/Amber
On (Green) = Clock B in slot 13 is the selected source clock
On (Amber) = Faulty or missing Clock B
Off = Clock B is good and not selected
SOURCE C
Green/Amber
On (Green) = The Bypass clock (Clock C) is the selected
source clock. See
On (Amber) = Faulty or missing Bypass clock
Off = Bypass clock is ignored, or good and not selected
SOURCE D
Green/Amber
On (Green) = The Expansion clock (Clock D) is the selected
source clock. The module is in an Expansion shelf
On (Amber) = Faulty or missing Expansion clock
Off = Expansion clock is ignored, or good and not selected
OUTPUT FAULT
Amber
On = Module has detected one or more faulty outputs
Off = All output signals are good
Table 8-9. E1/2048 kHz Output Module Specifications
Signal
120
Ω
75
Ω
E1
Specification
ITU-T G.703/9 (10/98)
ITU-T G.703/9 (10/98)
Signal
AMI or HDB3
AMI or HDB3
Format
CAS and CRC4 on
CAS and CRC4 on
Cable
Twisted pair, 120
Ω
Coaxial, 75
Ω
Maximum Peak Voltage
3.3 V
2.61 V
Minimum Peak Voltage
2.7 V
2.13 V
2048 kHz
Specification
ITU-T G.703/9 (10/98)
ITU-T G.703/9 (10/98)
Signal
Clock
Clock
Format
None
None
Cable
Twisted pair, 120
Ω
Coaxial, 75
Ω
Maximum Peak Voltage
1.90 V
1.50 V
Minimum Peak Voltage
1.00V
0.75 V
Table 8-8. E1/2048 kHz Output Module Status LED Indicators (Continued)
Indicator
Color
Description
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...