DS1 and E1 Output Module Default Settings
428
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
DS1 and E1 Output Module Default Settings
lists settings and factory defaults for the SSU-2000 DS1 and E1 Output
modules.
Table E-9. DS1 and E1 Output Module Default Settings
Setting
Factory
Default
Range
DS1 Output Module
Enable/Disable Outputs
Disabled
Settable for each output port
Minimum Clock Level
Acquire
Acquire/Lock
Bypass Mode
ON
ON – Clock C is selected if it is the only one available
OFF – Clock C is not selected even if no other clock is
available
Framing
ESF
D4/ESF
Line Length
0-133 ft
133-266 ft
266-399 ft
399-533 ft
533-655 ft
Zero Suppression
ON
ON – B8ZS
OFF – AMI
E1 Output Module
Enable/Disable Outputs
Disabled
Settable for each output port
Minimum Clock Level
Acquire
Acquire/Lock
Bypass Mode
ON
ON – Clock C is selected if it is the only one available
OFF – Clock C will not be selected even if no other
clock is available
Framing
CAS
CCS/CAS
Zero Suppression
ON
ON – HDB3
OFF – AMI
CRC
ON
ON/OFF
SSM Bit Selection
8
Possible SSM bit selection 4, 5, 6, 7, and 8