12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 321
Interactive Command Set
Use this command to set up the expected operation for the
specified alarm number. Only one alarm number can be passed if
you enter additional information.
The additional parameters that you can use are:
#
Alarm number. See
list of alarm numbers
DELAY
A supervisor can use this parameter to enter the
amount of time that an alarm condition must be active
before an actual alarm condition is generated. If an
alarm is specified to be Immediate, no delay time can
be entered. Delay times are in seconds.
Valid delays are 0 to 86,400 seconds (1 day). If the
original value is set to -1 (Immediate) for this command,
delay time cannot be set by the user.
IGNORE
Sets the alarm status level to IGNORE. This means that
no action is taken for an alarm condition.
REPORT
Sets the alarm status level to REPORT. This means that
a report-only message occurs for an alarm condition.
MINOR
Sets the alarm status level to MINOR.
MAJOR
Sets the alarm status level to MAJOR.
CRITICAL
Sets the alarm status level to CRITICAL.
Level 4
Same as Level 3 operation.
Remarks
Use of this command implies that the operator is querying the state
of the unit. All information is presented as concisely and completely
as possible. Each alarm is listed on a separate line.
Related
Restrictions None
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...