12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 357
Interactive Command Set
OUTPUT xAy BYPASS {ON|OFF}
OUTPUT xAy-z[&&z] {133FT|266FT|399FT|533FT|655FT}
OUTPUT xAy {CRC|ZS} {ON|OFF}
OUTPUT xAy SSM {4|5|6|7|8}
OUTPUT xAy-z[&&z] DUTYCYCLE {63/37|50/50}
OUTPUT xAy-z[&&z] COMPENSATE {275ft|550ft|825ft|
1100ft|1375ft|1650ft|1925ft|2200ft}
OUTPUT xAy FLTMODE {ON|OFF|AUTO}
OUTPUT xAy-z[&&z] {SQUELCH {{0–16}|DISABLE}
OUTPUT xAy-z[&&z] FREQUENCY {8...4096} in 8 kHz steps
OUTPUT xAy ISOLATE {ON|OFF}
Options are:
ESF|D4
Sets the T1 framing mode: ESF or D4.
CCS|CAS
Sets the E1 framing mode: CCS or CAS.
E1|2048
Sets the signal type for the E1/2048 kHz Output module
ENABLE|DISABLE
Enable or disable the specified output ports. If the
module is one of a redundant pair, this command only
affects the specified module’s ports.
LEVEL {ACQ|LOCK}
Sets the minimum clock level to ACQUIRE or LOCK
mode. The Output module turns off the output port if the
level is below the minimum clock level.
BYPASS {ON|OFF}
Enables or disables the bypass mode to support Clock
C.
133FT|266FT|399FT|533FT|655FT
Sets the line-length parameters for the output line
driver. For DS1 Output modules.
CRC {ON|OFF}
Enables or disables the CRC setting. For E1 and
E1/2048 kHz Output modules.
ZS {ON|OFF}
Enables or disables the zero suppression setting. For
the DS1, E1, and E1/2048 kHz Output modules.
SSM {4|5|6|7|8}
Sets the E1 SSM bit Position. For E1 and E1/2048 kHz
Output modules.
DUTYCYCLE
Sets the Composite Clock output to 63/37 or 50/50 duty
cycles. For CC Output module.
COMPENSATE
Sets current line compensation for the Composite Clock
output. For CC Output module.
FLTMODE
Allows the user to turn the output on or off when the
output level exceeds 2.1v threshold. Used for the 2048
kHz and RS-422 Output modules.
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...