12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 199
Output Module Reference Data
RS-422 Output Module
To enable the squelching feature, you must provision a “threshold” PQL value using
the OUTPUT command (for ICS mode) or the SET-PRMTR-CLKOUT command (for
TL-1 mode). A threshold PQL value of zero disables the squelch function. Threshold
PQL values above zero enable the squelch function; when the system PQL is
greater than the threshold PQL, the output is squelched.
For example, you can provision output ports 1 through 5 for a threshold PQL of 3
and you can disable squelching for ports 6 through 20 (PQL is set to 0). In this
example, if the system PQL is 1, 2, or 3, ports 1 through 20 generate outputs. If the
system PQL changes to 4 or higher, outputs on ports 1 through 5 are squelched
(disabled) and ports 6 through 20 continue to generate outputs. The response from
the Output Status command appears as shown below:
SSU+>out 2a10
2003-07-04T15:30:14 ID: SSU2000 Name:SSU
Module Name: Output RS-422
OUT STATUS
Clk Clk Stat
Port Status
1 1 1 1 1 1 1 1 1 1 2
Loc# Type Sta Sel
A B C D Redt Pql 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
---- ---- --- --- ------- ---- --- ----------------------------------------
2A10 ???? Ok
A
/Y/Y/N/Y
4
/S/S/S/S/S/ / / / / / / / / / / / / / /
OUTPUT SETUP
Loc# Type ZS
MinClk Bypass
---- ---- ---- ------ ------
2A10 ???? NA
ACQ
Off
Output fault action: Leave On
Squelch Level:
P[ 1]= 3, P[ 2]= 3, P[ 3]= 3, P[ 4]= 3, P[ 5]= 3,
P[ 6]= 0, P[ 7]= 0, P[ 8]= 0, P[ 9]= 0, P[10]= 0,
P[11]= 0, P[12]= 0, P[13]= 0, P[14]= 0, P[15]= 0,
P[16]= 0, P[17]= 0, P[18]= 0, P[19]= 0, P[20]= 0,
When the System PQL transitions to a PQL that crosses the user-defined Output-
Squelching PQL threshold, the SSU generates an alarm. The alarm message for
Alarm #14, Squelch, indicates which port(s) are in alarm due to the PQL threshold
being crossed. In the example Alarm message below, Port 20 of the RS-422 Output
module is in alarm.
2002-12-12T10:25:26 2A10 Maj Squelch, Below Prov, 00001
A five-digit hexadecimal number (consisting of 20 bits) at the end of the alarm
message identifies the affected port(s). Each digit represents four of the 20 ports on
the module; the first digit represents ports 1 through 4, the second digit represents
ports 5 through 8, and so on, as shown in
Figure 8-13. Using the Hex Number to Identify Output Ports
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...