12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 189
Output Module Reference Data
E1/2048 kHz Output Module
The port status message indicates the state of each port. The letter code for each
port is as follows:
F – port fault
N – port is disabled
blank – port is in normal service
The following example shows port 5 with an internal port fault, port 7 with an
external port fault, and ports 10, 11, and 12 disabled.
SSU+>out
OUT STATUS Clk Clk Stat
Port Status
1 1 1 1 1 1 1 1 1 1 2
Loc# Type Sta Sel A B C D
Redt PQL 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
---- ---- --- --- --------
---- --- ---------------------------------------
1A06 E12M Ok
A / / /N/N
4
/ / / / /I/ /E/ / /N/N/N/ / / / / / / / /
Functional Block Diagram
A simplified block diagram of the E1/2048 kHz Output module is shown in
Figure 8-8.
Block Diagram of the E1/2048 kHz Output Module