Interactive Command Set
326
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
COMM
Use this command to view and change the current communication port settings.
Level 0
Not applicable
Level 1
COMM [{L|A|B}]
Use this command to view the current settings for the specified
communications port. If you do not specify a communications port,
all communications ports are assumed. The communications port
settings include baud rate, character echo, current output line
termination, current session mode, and time-out value.
COMM BAUD {1200|2400|4800|9600|19200}
COMM ECHO {ON|OFF}
COMM EOL {CR|LF|CRLF}
Use this option to change the setting for the port over which you
are communicating. If your security access level is Level 1, the
setup changes are not stored in non-volatile RAM.
Options are:
BAUD
Sets the current baud rate setting. Only the baud rates
shown are valid.
ECHO
Enables or disables character echo on the terminal.
EOL {CR| LF| CRLF}
Sets the current End-Of-Line termination for output line.
CR
Sets the line termination to carriage return (0xD).
LF
Sets the line termination to line feed (0xA).
CRLF
Sets the line termination to carriage return, followed by
a line feed.
Level 2
Same as Level 1 operation, with the following additions:
COMM {L|A|B} BAUD {1200|2400|4800|9600|19200}
COMM {L|A|B} ECHO {ON|OFF}
COMM {L|A|B} EOL {CR|LF|CRLF}
COMM {L|A|B} MODE {ASCII|TL1}
COMM {L|A|B|TELNET|TL1} TIMEOUT {[5-43200]|NEVER}
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...