12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 135
Clock Module Reference Data
Type 1 Clock Module
Functional Specifications
lists the specifications for the Type 1 Clock module.
Acquire
Green
On = Clock module is acquiring a lock on a signal
Off = Not acquiring a lock on a signal
Locked
Green
On = Clock module is locked on a signal
Off = Clock module is not locked on a signal
Holdover
Amber
On = Clock module is in Holdover mode of operation
Off = Clock module is not in Holdover mode
Table 6-6. Type 1 Clock Module Specifications
Performance Characteristic
Specification
Holdover Stability
0 to 24 hrs @ –5 to +45 C
±2 x 10
-9
(after 30 days operation)
Numeric Controlled Oscillator
(NCO) PLL lock range
±5 x 10
-4
Tuning Resolution (Locked Mode)
<1 x 10
-13
Warm-up Time (Warm-up Mode)
20 minutes
Wander Output (Holdover)
Includes effects of all SSU-2000 modules: Compliant with
clock levels per ITU-T G.812, Type 1 and ETSI EN300 462-4
Jitter (Locked or Holdover)
< 4 ns p-p (measured at the CLKA/BIN 8 kHz output)
Table 6-5. Type 1 Clock Module Status LED Indicators (Continued)
Indicator
Color
Description
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...