12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide
61
Installing the SSU-2000
Preliminary Procedures
Installation Tools and Materials
The following required standard tools and materials (not supplied) are required for
installing the SSU-2000:
Standard tool kit
Cable ties or acceptable cable clamps
16 AWG (minimum) wire for –48V, RTN, and frame ground
18 AWG wire for connecting office alarms
22 AWG shielded twisted pair wire-wrap cable (Amp #640433-7 or equivalent)
Wire-wrap tool
No. 10 screws, flat washers, and locking washers for mounting the equipment rack
Digital Voltmeter
Straight-through RS-232 cable
Laptop or PC with a terminal emulation program such as HyperTerminal or
ProComm Plus
Electromagnetic Interference (EMI) Considerations
Electromagnetic interference (EMI) from one instrument can adversely affect the
operation of nearby equipment. To prevent the SSU-2000 from interfering with other
equipment, it must be installed and operated as described in the following
paragraphs.
All cables connected to the SSU-2000 should be shielded with metal connector
shells. The connectors on the rear panel of the shelf are shielded, with the shields
connected to frame ground. Follow local procedures for shield grounding. The
screws on all cables must be securely fastened to their corresponding connectors
on the rear of the unit. While the unit is in operation, there must be a module or
blank panel installed in every slot. Also, the captive screws, located at the top and
bottom of the module panel, must be properly secured.
Caution:
To avoid electrostatic discharge (ESD) damage to
equipment, follow the ESD precautions as listed in this guide.
Recommendation:
Symmetricom recommends that you follow all
applicable local building electrical codes when installing the
SSU-2000.
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...