12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 161
Input Module Reference Data
1-Port and 3-Port DS1 Input Modules
Configuration Options
The factory settings and ranges for all DS1 Input module software parameters are
listed in
.
PORT 3 REF
Green/Amber
On (Green) = Selected
On (Amber) = Not good and ignored
Off = Ignored or good and not selected
PORT 3 INPUT
Green/Amber
On (Green) = Selected
On (Amber) = Not good and ignored
Off = Ignored or good and not selected
Table 7-8. DS1 Input Module Configuration
Configuration Setting
Factory Default
Range
Framing Enabled
On/On/Off
On/Off
Input Frequency
(for unframed signals)
10 MHz
1 MHz, 1.544 MHz, 2.048 MHz, 5 MHz, 10MHz
Framing Type
ESF
D4 or ESF
Zero Suppression
On
On/Off
CRC
Off
On/Off
SSM
Off
On/Off
Provisioned PQL
3/4/3
1 to 16
Priority
0
0 to 10 (0 = Monitor)
Cesium Fault Nominal
Low
Low/High/Off
Input Signal Error Limit
10 seconds
1 to 100 for LOS and AIS
1 to 10000 for BPV, CRC and OOF
MTIE T10 Limit1
325/1000/325
0 to 100000
MTIE T10 Limit2
330/1010/330
0 to 100000
MTIE T100 Limit1
550/2000/550
0 to 100000
MTIE T100 Limit 2
560/2010/560
0 to 100000
MTIE T1000 Limit1
1010/2000/1010
0 to 100000
MTIE T1000 Limit2
1020/2010/1020
0 to 100000
MTIE T10000 Limit 1
1100/2835/1100
0 to 100000
Table 7-7. DS1 Input Module Status LED Indicators (Continued)
Indicator
Color
Description
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...